Temperature measurement up to 500 °C under high pressure.

2,000–7,000 bar

BrandSITEC-Sieber Engineering AG — Switzerland
CategoryHigh-Pressure Components
Catalogue page770.04
Pressure / capacity2,000–7,000 bar
Max. pressureThermocouples 7,000 bar; Pt100 4,000 bar
Max. temperature (catalogue table)300 … 500 °C, depending on model
MaterialsAISI 316L / Inconel 600 (tip sheath)
AccuracyTC class 1 (DIN EN 60584-2); Pt100 class B (DIN EN 60751-2)
H₂ compatibilityConfirmed by official documentation
Verification statusVerified
Documentation sourceCompiled from official SITEC-Sieber Engineering AG documentation.

Final technical specifications are confirmed in writing with H2X before ordering.

Technical Data

From the Official Catalogue

Key Features

  • Thermocouples (type K chromel-alumel and type J) and Pt100 resistance thermometers for fast, reliable temperature measurement in HP vessels and optical cells
  • Very thin thermocouple tip in direct contact with the fluid (Inconel 600 sheath) for a fast response
  • Two-wire Pt100 thermometers recommended for industrial applications
  • Direct installation in standard SITEC HP connections 1/4 HP, 3/8 HP and 9/16 HP
  • Integrated LEMO 1 connecting plug; pin connector and extension wire ordered separately
  • Standard sensor lengths L: 3, 7, 9, 12, 16, 22, 26, 45, 90 and 145 mm (Pt100 min. 26 mm); type K from stock

Source: official SITEC-Sieber product catalogue (page 770.04). Request the datasheet for model, part-number and dimension tables.